Procedure - Solid Samples
Instrument calibration/drift correction.
Add approximately 0.05 g of *** Graphite Powder to a *** Graphite Crucible.
Firmly place the crucible on the lower electrode tip or appropriate autoloader position.
Press the Analyze button on the instrument screen, the lower electrode will close and the analysis sequence will start and end automatically.
Repeat steps 3b through 3j a minimum of three times for each calibration/drift standard used.
Calibrate/drift following the procedure outlined in the operator's instruction manual.
Procedure – Powder/Chip Samples
Determine the instrument blank.
Press the Analyze button on the instrument screen, the lower electrode will close and the analysis sequence will start and end automatically.
Repeat steps 2b through 2g a minimum of three times.
Set the blank following the procedure outlined in the operator's instruction manual.
Instrument calibration/drift correction.
Login a minimum of three Standard reps.
Weigh approximately *** grams of a calibration/drift standard into a *** Nickel Capsule; enter the mass and standard identification into appropriate rep fields. If applicable, place the nickel capsule in the appropriate autoloader position.
山西專業(yè)分析儀采購高級(jí)診斷程序包括全數(shù)字化的在線操作手冊、維護(hù)模擬演示、圖片說明等提供快速指導(dǎo)。
氧氮?dú)浞治鰞x的常見故障及解決方法:
氧和氮空白值超過20。這是由于氣流小,不能將爐子中的空氣驅(qū)趕出去??烧{(diào)節(jié)氣體流量,調(diào)節(jié)載氣壓力在0.2~0.4MPa。接通儀器載氣,放一個(gè)石墨坩堝在下電極上,打開主電源開關(guān),點(diǎn)擊軟件上的關(guān)爐按鈕,關(guān)閉爐子并等待10s。調(diào)節(jié)流量調(diào)節(jié)器,直到流量計(jì)a顯示為30L/h,打開爐子。調(diào)節(jié)調(diào)節(jié)器直到流量計(jì)b顯示為50L/h,再次關(guān)閉爐子。如果以上設(shè)置不穩(wěn)定,則增加流量至100L/h,反復(fù)調(diào)節(jié)直至儀器穩(wěn)定。
Procedure - Solid Samples:
--Instrument calibration/drift correction.
Place the nickel basket containing the calibration/drift standard into the open port at the top of the loading head.
Press the Analyze button on the instrument screen again, the loading head slide-block will close and the lower electrode will open.
Clean the upper and lower electrode manually, or, if applicable, remove the crucible and press the analyze button to clean with the automatic cleaner.
LECO—Your source for total analytical solutions
CS CS 844 and 744 Series: Carbon/Sulfur by Combustion
Carbon and sulfur determination by combustion infrared detection
Quick, accurate, and affordable determination for both production control and research
Calibration, analysis, evaluation, and diagnostic functions accessible via user-friendly brand software
GDS GDS 500A and 850A Atomic Emission Spectrometers
Spectral range from 120 to 800 nm
Continuous profile of concentration/thickness
Large, dynamic range with concentrations from ppm to 100% by weight
Short analysis time (minutes)
氧氮?dú)浞治鰞x選哪家?給您推薦上海禹重!浙江LECO氧氮?dú)浞治鰞x價(jià)格
力可創(chuàng)新的批次和重復(fù)樣品數(shù)據(jù)分組功能極大簡化了樣品結(jié)果輸出和結(jié)果標(biāo)準(zhǔn)偏差的自動(dòng)計(jì)算。浙江LECO分析儀廠家直銷
ONH836系列:氧氮?dú)浞治鰞x(熔融法)
軟件特點(diǎn)和優(yōu)勢
Cornerstone氧氮?dú)浞治鲕浖殖?個(gè)主要部分:分析、診斷、設(shè)定、儀器,界面可以快速導(dǎo)航和組織。工具條、滑動(dòng)條和下拉式菜單簡化了校正和數(shù)據(jù)處理的參數(shù)設(shè)定。分析軟件同時(shí)包括實(shí)時(shí)的環(huán)境參數(shù)的監(jiān)測,提供完整的系統(tǒng)圖表模擬。高級(jí)診斷程序包括全數(shù)字化的在線操作手冊、維護(hù)模擬演示、圖片說明等提供快速指導(dǎo)。Cornerstone氧氮?dú)浞治鲕浖瑫r(shí)支持***的數(shù)據(jù)文檔格式和可變的報(bào)告格式。 浙江LECO分析儀廠家直銷